CHTA BETWEEN BEARINGS DIFFUSER CASING, UTILITY BARREL PUMP

CHTA Between Bearings Diffuser Casing Utility Barrel Pump designed for high-efficiency industrial applications.

IntroductionFeaturesLiterature

CHTA Between Bearings Diffuser Casing Utility Barrel Pump designed for high-efficiency industrial applications.

CHTA BETWEEN BEARINGS DIFFUSER CASING, UTILITY BARREL PUMP

BRAND DESCRIPTION
FLOWSERVE

The Flowserve CHTA is a horizontally mounted, multistage, between-bearings barrel pump engineered for high-pressure utility applications such as boiler feedwater and startup services in thermal and combined cycle power plants. Its double-case, radially split inner casing design ensures structural integrity under extreme operating conditions, while the precision-cast diffusers and tandem impellers deliver efficient hydraulic performance. The CHTA’s robust construction and advanced features make it a reliable choice for demanding industrial processes.

The Flowserve CHTA, with either a double suction or a single suction first stage impeller, is a double casing, multistage barrel pump. The CHTA is specifically designed and built for high temperature, high pressure and high flow applications, including boiler feedwater and water injection.

  • Applications:
    Boiler Feed
  • Industries:
    Power Generation

Precision Cast Diffusers minimize bearing spans, thereby increasing pump reliability and efficiency.

Suction and Discharge Connections can be located on the top or the bottom of the barrel and may be supplied with flanged or weld end design to suit installation requirements.

Forged and Hardened Stainless Steel Balance Drum is conservatively sized to completely unload the thrust bearing at all operating points.

Self-Aligning, Double-Acting Tilt-Pad Thrust Bearings are conservatively rated to carry axial loads that may be encountered during transient operating conditions.

Precision Cast Tandem Impellers are positively locked and keyed to the shaft.

Serrated Impeller Running Fits reduce the effects of rotor contact during system upsets or turning gear operation.

Operating Parameters

  • Flows to 5250 m3/h (23 000 gpm)
  • Heads to 4300 m (14 000 ft)
  • Discharge pressures to 450 bar (6525 psi)
  • Temperatures to 250°C (480°F)
  • Speeds to 6000 rpm