WUC ISO 13709/API 610 (VS6) Vertical, Double Case, Multistage Pump

Flowserve WUC API 610 VS6 Vertical Double Case Multistage Pump for high pressure industrial service

Introduction Features Literature

WUC ISO 13709:API 610 (VS6) Vertical, Double Case, Multistage Pump

WUC ISO 13709/API 610 (VS6) Vertical, Double Case, Multistage Pump

Brand: Worthington
Description:

The Flowserve WUC is a vertical double case multistage centrifugal pump designed to meet ISO 13709 and API 610 (VS6) standards, ideal for high-pressure fluid transfer in refineries, petrochemical plants, power stations, and offshore platforms. Its rugged construction ensures excellent hydraulic stability, minimal vibration, and reliable performance in demanding deep well and wet pit applications.

Compliant with ISO 13709/API 610 (VS6), the Flowserve WUC vertical turbine is a radial flow or axial flow type, multistage, heavy-duty double casing pump. It is designed for continuous unspared duty at a variety of high-pressure services, operating at temperature extremes and handling difficult liquids.

WUC Multistage Pump Applications

Acid Transfer, Catalytic Cracking, Condensate Extraction, Crude, Product and CO2 Pipeline, Dewatering and Water Supply (mining), Water Treatment, Hydrocracking, Hydrotreating, Industrial Gases, LNG, Snowmaking, Distillation (oil and gas)

  • Industries:
    Power Generation, Water Resources, Oil and Gas, General Industries, Mining, Chemical Processing
  • Standards:
    API682, API610

Flanged Spacer Type Coupling permits easy maintenance of thrust bearings and mechanical seals without disturbing or removing driver.

Separate Axial Thrust Bearing Assembly designed to withstand total hydraulic thrust and rotor weight.

ISO 21049/API 682 Compliant Mechanical Seal Chamber accommodates all cartridge mounted seal designs, including: single and dual pressurized or unpressurized liquid; and gas designs.

Screen-Type Non-Sparking Coupling Guard provides safety while allowing visual inspection of coupling and mechanical seal areas.

Casing and Impeller Wear Rings feature a minimum 50 Brinell hardness difference between them. These rings prevent galling, allow economical retention of operating efficiency and maintain mechanical stability.

WUC Multistage Pump Operating Parameters

  • Flows to 3000 m3/h (13 200 gpm)
  • Heads to 2000 m (6560 ft)
  • Pressures to 200 bar (2900 psi)
  • Temperatures from -200°C (-328°F)  to 350°C (660°F)

WUC ISO 13709/API 610 Pump Poster

WUC Pump Poster

WUC Pump Bulletin

Handling high pressure deep well or offshore applications? The WUC vertical pump delivers robust multistage performance under API compliance. Let’s discuss your operating parameters and tailor a WUC solution for your system