WM2 API 610 (OH5), Overhung, Close Coupled, Vertical In-Line, Low Flow, Two Stage Pump

Flowserve WM2 Two-Stage Vertical In-Line API 610 OH5 Pump for Low-Flow High-Head Applications

Introduction Features Literature

WM2 API 610 (OH5), Overhung, Close Coupled, Vertical In-Line, Low Flow, Two Stage PumpWM2 API 610 (OH5), Overhung, Close Coupled, Vertical In-Line, Low Flow, Two Stage Pump

Brand: IDP
Description:

The Flowserve WM2 is a two-stage, close-coupled vertical in-line pump designed in accordance with ISO 13709 / API 610 (OH5) standards. Engineered for low-flow, high-head services, the WM2 pump features a compact design that eliminates the need for a separate bearing housing. Its modular construction allows for over 100 Best Efficiency Point (BEP) fits within a single pump size, ensuring optimal performance across various applications. The WM2 is ideal for industries such as oil and gas, petrochemical processing, and high-temperature services, where space-saving and reliable operation are critical.

The Flowserve WM2 is the space-saving, close coupled configuration of the HWM2 pump. This two-stage pump is designed specifically for low flow, medium to high head operation and is fully compliant with API 610 (OH5), latest edition.

WM2 Two Stage Pump Applications

Boiler Circulation, Gas Industry Service , General Purpose, Water, Petrochemical Processing, Petroleum Distribution, High Temperature Service

  • Industries:
    Utilities, SAGD, NGL, Logistics and Tank Farm, LNG, Hydrotreating, Hydrocraking, Gas Treatment, Gas-to-Liquids, Distillation, Crude Handling and Treatment, Catalytic Cracking, Water Handling and Treatment
  • Standards:
    API610

Low Flow, High Head Design for smooth, stable operation outside the preferred operating region specified by API 610.

Modular Design provides more than 100 BEP fits in one pump size.

Replaceable Volute Inserts to handle changing operating conditions.

Radial Blade Impeller provides a continuously rising performance curve with low flow stability. Impeller is dynamically balanced to limit vibration and ensure smooth operation over wide flow range.

Close Coupled Design to latest edition of API 610.

API 682 Seal Chamber accommodates a wide variety of seal configurations including dual pressurized and unpressurized cartridge types for the most severe services.

Features:

  • Optional inducer for low NPSH requirements
  • Other configurations
    • WM (low flow, high head, single stage)
  • Operating parameters
    • Flows to 30 m3/h (130 gpm)
    • Heads to 440 m (1450 ft)
    • Pressures to 60 bar (850 psi)
    • Temperatures from -45°C (-50°F) to 260°C (500°F)

HWM, HWM2, WM, and WM2 Pumps Bulletin