CM MAG-M
Pump construction
Close-coupled drivers are conventional drivers mounted directly to pumps frame. No base, coupling or guards are required for this mounting style.
Connections:
Universal fl anges rating according to DIN Norms Class PN16 – 40 & ANSI B16.5 Class 150 (standard). Threaded BSP (GAS) & NPT (available on request). Other on request

CN MAG-MS API
Pump construction
- Top-Top, center line mounted, for high nozzles loading capability.
- Heavy duty API 685 – 2nd Edition, BB5 radially split style, bare frame mounting.
Connections
• Flange rating per DIN Standard PN 40-63-100
• Flange rating per ANSI B16.5 300# and 600#
• Other on request.

CN MAG-M
Operating limits
- Maximum capacity up to 4000 mc/h,
- Differential head up to 155 m.
- Temperature range: from -185 °F (-120 °C) to +662°F (+350°C) without external cooling.
- The maximum allowable working pressure 16 bar for the standard version and 150 bar for HP Version, higher pressure version available on request.

CN MAG-M API
Operating limits
– Maximum capacity up to 4000 mc/h, differential head up to 220 m.
– Temperature range: from -185°F (-120°C) to +662°F (+350°C) without external cooling.
– The maximum allowable working pressure 50 bar for the standard version and 150 bar for HP Version, higher pressure version available on request.

CNV MAG-M
Pump construction
- Vertical construction adopts V1 IEC motor standard.
- Base flange designed on customer specification.
- Connections:
- Threaded BSP (GAS) & NPT.
- Flange rating per DIN Norms Class PN16 – 40
- Flange rating per ANSI B16.5 Class 150 and 300 lbs

CR MAG-M API
Operation limits
Maximum capacity: up to 4000 mc/h, differential head up to 220 m.
Temperature range: from -185 °F (-120 °C) to +662 °F (+350 °C) without external cooling.
The maximum allowable working pressure 50bar for the standard version and 150bar for HP Version, higher pressure version available on request up to 842°F (+450°C).

CN MAG-MV
Pump construction
Vertical construction adopts V1 IEC motor standard. Base flange designed on customer specification.
Connections:
Threaded BSP (GAS) & NPT. Flange rating per DIN Norms Class PN16 – 40 Flange rating per ANSI B16.5 Class 150 and 300 lbs